India’s first independent NABL Accredited metallographic testing lab for crossection analysis

DSC Testing

DSC Testing

Our Testing

Differential Scanning Calorimetry (DSC)

Differential scanning calorimetry (DSC) is a thermal analysis process that measures changes in heat flow as a sample transforms from one state to another — changing from a solid to a liquid, for example. DSC is also used to observe more subtle physical changes, such as glass transitions, crystallization, and oxidation..

DSC is frequently used as a quality control instrument in industrial settings, especially in the manufacture of plastics and medications.

dsc testing

What is Differential Scanning Calorimetry Testing?

DSC provides insights into the impact of thermal energy on materials. This makes DSC an excellent analysis tool for quality control if concerned about how temperatures will affect product stability or viability. In particular, you might consider DSC when you need to:

Study polymer curing
Determine composition variations
Measure the melting point
Identify the glass transition temperature
Assess the degree of crystallinity and oxidation

DSC Specifications

Thermal Analysis: DSC 4000 Differential Scanning Calorimeters
Temperature Performance Range -100 ˚C to 450 ˚C
Accuracy ±0.1 ˚C
Precision ±0.02 ˚C
Data points/sec 10
Controlled heating rates 0.1 to 100 ˚C/min
Controlled cooling rates 0.1 to 100 ˚C/min
Cooling times – intracooler (100 ˚C to 0 ˚C) Under 4 minutes

We are capable to perform the glass Transition temperature of below listed Materials as per ASTM standard:

Ploymers, Polymer Blends
Rubber
Thermo-Plastic
PCB Laminates
Nylon
Amorphous metals
Proteins
Sugars
Adhesives

DSC Analysis of Polymers

Differential Scanning Calorimetry is a particularly useful tool to analyze polymers. DSC can reveal several important thermal transitions in these materials. Identification of a polymer’s melting, crystallization, and glass transition temperatures can help us characterize and compare such materials. Our experts can compare this data with well-cataloged standard references that exist for most polymers. For example, the thermograph below shows the results of a second heating applied to a sample. The two distinct thermal transition points (labeled) aided in its identification as Nylon 6.

In addition to identification, our experts can utilize DSC analysis for many other purposes. We can compare the crystallization and melting points from the first heating with standard references to determine the crystalline content of a known polymer. Identification of boiling points can permit the detection of individual plasticizers’ in a sample. We can also use Oxidative Onset Temperature (OOT) to analyze the thermal degradation of polymers. Because DSC measures numerous characteristic properties of a sample, its applications are vast.

The industries we serve are

One of the most precise techniques to obtain the Tg of the polymers is the differential scanning calorimetry, DSC (ISO 11357-3, ASTM E1356).

Packaging
Food and Beverage
Plastics
Polymers
Heat Transfer
Chemical
DSC (Melting point, Glass Transition, Specific heat, Heat capacity, Crystallinity, Oxidation Induction Time)

We do check following parameters using Differential Scanning Calorimetry (DSC) –(- 100 deg C to 450 deg C)

Heat Capacity.
Polymorphism
Melting Point.
Melting Range
Glass Transition
Thermal Stability.
Crystallinity
Oxidation Induction Time(OIT)
Purity
Latent Heat
Specific Heat
× How can I help you?